ID: 133
Features Include:
- Performance - a 2(N+1) 11,300 kVA UPS system with multiple redundant power distribution paths and connection to PGE Sunset Reliability Center allows access to
redundant power grids.
-
Network and cooling - Top network providers have diverse underground entry points. The cooling system is fully redundant with 2,220 tons of capacity and 250+ Watts/sqft high density capacity vailability.
-
Satisfaction - customers receive a 100% satisfaction guarantee, including SLA for power, bandwidth and network services availability.
-
Expert service - On site staff helps maintain uptime through remote hands capabilities, ticket tracking, event notification and more.
Shopping Cart Information:
The Cart's listings can be displayed by clicking on the cart-icon located on the upper-right of this screen.
To hide the Cart, click on any portion of the main-display's contents. The Cart can be redisplayed by
clicking on the cart-icon again.
To go back to the Map, click on the Gray Button located on the upper-left of this screen.
Have a Question? Call Us @ 507.398.5964
Features Include:
- Performance - a 2(N+1) 11,300 kVA UPS system with multiple redundant power distribution paths and connection to PGE Sunset Reliability Center allows access to
redundant power grids.
-
Network and cooling - Top network providers have diverse underground entry points. The cooling system is fully redundant with 2,220 tons of capacity and 250+ Watts/sqft high density capacity vailability.
-
Satisfaction - customers receive a 100% satisfaction guarantee, including SLA for power, bandwidth and network services availability.
-
Expert service - On site staff helps maintain uptime through remote hands capabilities, ticket tracking, event notification and more.
For more information
... contact
Bob Dubke - Broker
Bob@DataCenterBrokers.com
507-398-5964
DataCenterBrokers.com
With 138,000 sqft of raised floor, the Brookwood data center features fully redundant UPS power equipment, in addition to an energy efficient cooling system. ViaWest uses 24x7 local engineers and service staff experts to run this data center.
Oregon and the city of Hillsboro offer business tax incentives, tax credits, and tax abatement programs.
SITE INFORMATION
| Description |
● | 138,000 sqft of raised floor. |
● | Private suites and cages. |
● | Unit level-available in full, half, and quarter cabinet increments. |
● | Certified data center smoke detection system. |
● | Certified VESDA incipient smoke detection. |
● | Dual-Interlock pre-action dry pipe sprinkler system. |
● | Clean agent fire extinguishers placed throughout the facility. |
ENVIRONMENT
| Description |
● | 6,000 tons of redundant cooling capacity. |
● | Highly energy effecient cooling system (1.3 PUE expected). |
● | High density pods (700+ watts/spft. |
● | Anti-static raised flooring with designated cable runs and cooled air delivery. |
● | Hot aisle/cold aisle configuration. |
● | Fully cabled for typical customer applications. |
● | Waterside economizers allow for free environmental cooling. |
CONNECTIVITY
| Description |
● | Multiple redundant fiber optic telecommunication networks delivered via Telcordia/Bellcore standards with diverse conduit and entrance facilities. |
● | Telecommunication services available from T1 to multiple OC192. |
● | Ethernet services available from 5 Mbps to multiple 10 Gbps. |
● | Multiple telecommunications providers available including Frontier, Integra, twtelecom, LS Networks, Level3, Comcast, Zayo, and CenturyLink.
|
POWER
| Description |
● | A and B source power circuit delivery capabilities. |
● | Multiple medium voltage (13.2kV class) utility power feeds. |
● | 29 MW redundant, fault tolerant diesel power generation capacity. |
● | 50,000 gallon diesel fuel capacity. |
● | 18 MW redundant, fault tolerant UPS capacity. |
● | PLC-based fault tolerant closed transition switchboard. |
● | Redundant battery strings. |
● | Multiple redundant power distribution paths. |
● | Branch circuit monitoring system. |
COMPLIANCE
| Description |
● | ViaWest has a dual-standard SSAE 16 and ISAE 3402 Service Organization Control
(SOC) 1 Type II, SOC 2 Type II, and SOC 3 reports covering each of ViaWest’s
data centers to include operations, policies and procedures, and physical and
environmental security controls. |
● | ViaWest also has facility-specific PCI and HIPAA compliance reports for physical security and information security policies. |
● | ViaWest enables businesses to become compliant in the Financial, Healthcare and Federal industries that require regulatory authority of PCI DSS, HIPAA, FISMA, NIST 800-53
and ITAR standards. |
● | ViaWest annually registers its adherence to the US-EU Safe Harbor Privacy framework. |
SECURITY
| Description |
● | 24x7 access via dual factor authentication. |
● | Monitored security cameras and intercom system. |
● | Security fence around complex perimeter. |
● | Power delivery, generator and diesel fuel infrastructure maintained and under 24x7 surveillance. |