ID: 134
Features Include:
- Performance - the Power Usage Effectiveness (PUE) is projected at 1.2, the lowest PUE of any colocation facility in the industry.
-
Network and cooling - Top network providers have diverse underground entry points to the data center. The cooling system is fully
redundant with 3,000 tons of capacity and 700+ Watts/sqft high density capacity availability.
-
Satisfaction - customers receive a 100% satisfaction guarantee, including SLA for power, bandwidth and network services availability.
-
Expert service - ViaWest's dedicated, onsite staff of trained engineers helps maintain uptime through remote hands capabilities, ticket tracking, event notification and more.
Shopping Cart Information:
The Cart's listings can be displayed by clicking on the cart-icon located on the upper-right of this screen.
To hide the Cart, click on any portion of the main-display's contents. The Cart can be redisplayed by
clicking on the cart-icon again.
To go back to the Map, click on the Gray Button located on the upper-left of this screen.
Have a Question? Call Us @ 507.398.5964
Features Include:
- Performance - the Power Usage Effectiveness (PUE) is projected at 1.2, the lowest PUE of any colocation facility in the industry.
-
Network and cooling - Top network providers have diverse underground entry points to the data center. The cooling system is fully
redundant with 3,000 tons of capacity and 700+ Watts/sqft high density capacity availability.
-
Satisfaction - customers receive a 100% satisfaction guarantee, including SLA for power, bandwidth and network services availability.
-
Expert service - ViaWest's dedicated, onsite staff of trained engineers helps maintain uptime through remote hands capabilities, ticket tracking, event notification and more.
For more information
... contact
Bob Dubke - Broker
Bob@DataCenterBrokers.com
507-398-5964
DataCenterBrokers.com
This ViaWest data center is one of three in Nevada. The Lone Mountain data center is an innovative data center, with 74,000 square feet of raised
floor, and is designed to be concurrently maintainable and fault tolerant,. ViaWest uses 24x7 local engineers and service staff experts to run this data center.
SITE INFORMATION
| Description |
● | 74,000 square feet raised floor. |
● | Private suites and cages. |
● | Customer office space. |
● | Unit level-available in full, half, and quarter cabinet increments. |
● | Certified data center smoke detection system. |
● | Certified VESDA incipient smoke detection. |
● | Dual-Interlock pre-action dry pipe sprinkler system. |
● | Clean agent fire extinguishers placed throughout the facility. |
ENVIRONMENT
| Description |
● | Designed as concurrently maintainable and fault tolerant. |
● | 3,000 tons redundant, fault tolerant cooling capacity. |
● | Highly energy efficient cooling system (1.2 expected PUE). |
● | High density capacity (700+ watts per square foot). |
● | Anti-static raised flooring. |
● | Hot aisle-cold aisle configuration. |
● | Fully cabled for typical customer applications. |
● | Green Globes and Energy Star certified expected. |
● | Energy efficient LED lighting. |
COMPLIANCE
| Description |
● | ViaWest has a dual-standard SSAE 16 and ISAE 3402 Service Organization Control
(SOC) 1 Type II, SOC 2 Type II, and SOC 3 reports covering each of ViaWest’s
data centers to include operations, policies and procedures, and physical and
environmental security controls. |
● | ViaWest also has facility-specific PCI and HIPAA compliance reports for physical security and information security policies. |
● | ViaWest enables businesses to become compliant in the Financial, Healthcare and Federal industries that require regulatory authority of PCI DSS,
HIPAA, FISMA, NIST 800-53
and ITAR standards. |
● | Phase II has been awarded Tier III certification of Constructed Facility by the Uptime Institute. |
● | ViaWest annually registers its adherence to the US-EU Safe Harbor Privacy framework.
|
POWER
| Description |
● | A and B source power circuit delivery capabilities. |
● | Multiple medium voltage (15KV class) utility power feeds. |
● | 16 MW redundant, fault tolerant diesel power generation capacity. |
● | 30,000 gallon diesel fuel supply. |
● | 9 MW redundant, fault tolerant UPS capacity. |
● | PLC-based fault tolerant closed transition switchboard. |
● | Redundant battery strings. |
● | Multiple redundant power distribution paths. |
● | Branch circuit monitoring system. |
CONNECTIVITY
| Description |
● | Multiple redundant fiber optic telecommunication networks delivered via Telcordia/Bellcore standards with diverse conduit and entrance facilities. |
● | Telecommunication services available from T1 to multiple OC192. |
● | Ethernet services available from 5 Mbps to multiple 10 Gbps. |
● | Carriers include AT&T, CenturyLink, Comcast, Level 3 Communications, NTT Communications, Sprint, Time Warner Cable, Verizon, Windstream, XO Communications, and Zayo. |
SECURITY
| Description |
● | 24x7 access via dual factor authentication. |
● | 24x7 on-site security personnel. |
● | Monitored security cameras and intercom system. |
● | Security fence around complex perimeter. |
● | Power delivery, generator and diesel fuel infrastructure maintained and under 24x7 surveillance. |