ID: 142
Features Include:
- Dual powerfeeds from three substations, equipped with ATSs
-
Optimal location for carrier PoP and or traditional cage deployments
-
Traditional cabinet and cage options as well as 1U standard connections product
-
Access to 35+ networks in access controlled Fiber Vault/Meet-Me-Room
-
Access to connectivity to other tenants in the building
-
24/7 on-site technicians
-
24/7 building security, anti-tailgating mantrap to data center
-
SSAE 16 SOC1 Audited
Shopping Cart Information:
The Cart's listings can be displayed by clicking on the cart-icon located on the upper-right of this screen.
To hide the Cart, click on any portion of the main-display's contents. The Cart can be redisplayed by
clicking on the cart-icon again.
To go back to the Map, click on the Gray Button located on the upper-left of this screen.
Have a Question? Call Us @ 507.398.5964
Features Include:
- Dual powerfeeds from three substations, equipped with ATSs
-
Optimal location for carrier PoP and or traditional cage deployments
-
Traditional cabinet and cage options as well as 1U standard connections product
-
Access to 35+ networks in access controlled Fiber Vault/Meet-Me-Room
-
Access to connectivity to other tenants in the building
-
24/7 on-site technicians
-
24/7 building security, anti-tailgating mantrap to data center
-
SSAE 16 SOC1 Audited
For more information
... contact
Bob Dubke - Broker
Bob@DataCenterBrokers.com
507-398-5964
DataCenterBrokers.com
One of two data centers (12,000 sqft) located in the INFORMART, the preeminent carrier hotel in Dallas - 35+ carrier networks.
SITE INFORMATION
Item | Description |
Colocation Space | 12,000 sqft |
Configurations | Cabinets (24 x 48in), customizable cage sizes
|
CONNECTIVITY
Item | Description |
Meet-Me-Room | Yes |
Network Neutral | Yes |
Interconnections | 35+ carriers (including into Central America) |
Cross Connects | Fiber and copper (MMR) |
Conduit Options | Yes, within the building
|
ENVIRONMENTAL CONTROLS
Item | Description |
Cooling Configuration | Overhead ducted supply in cold/hot aisle |
Cooling Type | Perimeter CRAC |
Redundancy | N+1 |
POWER
Item | Description |
Utility Capacity | 2,078kW |
Generator Capacity | 1,350kW |
UPS Capacity | 1,240kW |
Load Design | 100W/sqft, 8kW/cabinet |
Power Feeds | Two sources from three different utility substations |
Backup | 1.5mW diesel Caterpillar generator with dual starters & batteries |
Redundancy | 2N UPS, Canara UPS and battery monitoring |
SECURITY
Item | Description |
SSAE Audited | SSAE 16 SOC 1 for PCI compliance |
Monitored | 24/7 INFOMART and full on-site security |
Compliance | HIPAA, PCI, and IRS 1075 |
Site Access | Man-traps with keycard and biometrics |
CCTV | Yes |
All information is deemed reliable, but not guaranteed.
Copyright 2007-2023 Technology Ideas Corporation. All rights reserved.